Fire-Rated Cabinets - Flame-Shield® Option
Supplemental* Submittal and Detail Sheet for Fire-Rated: Architectural Series, Gemini Series, Cameo Series, Medallion Series, Vista Series, Rota Series. Fire Hose & Valve Cabinets, and Fire Blanket Cabinets.
(NOTE: This supplemental Fire-Rated Submittal & Detail Sheet must be combined with the respective Submittal & Detail Sheet for the appropriate above listed cabinet series.)
PROJECT:LOCATION:
MODEL NUMBER: FSQUANTITY:
ARCHITECT:CONTRACTOR:
DATE:DISTRIBUTOR:
SPECIFICATIONS:
The Flame-Shield fire-rated option is available for a variety of Larsen's fire extinguisher, fire department valve, fire hose, and fire blanket cabinets. It is designed specifically to maintain the integrity of one and two hour fire walls with all Larsen's recessed and semi-recessed cabinets. Warnock-Hersey has certified and listed Larsen's Flame-Shield fire-rated option for one and two-hour combustible and non-combustible wall systems to meet the requirements of UBC Standard 43-B (ASTM E-814).

All boxes for cabinets with the Flame-Shield fire-rated option have a double wall of cold-rolled steel with baked acrylic enamel finish. The space between the double walls is lined entirely with 5/8" thick fire barrier material. All Larsen's cabinets with the Flame-Shield fire-rated option are provided with factory supplied anchoring devices. Top view of 1 asn 2 hour wall systems

STEP 1: Select fire-rated cabinet model number from the dimensions on the back of this sheet (or on attached sheet) and indicate on the top of this sheet. Because rough opening dimensions for fire-rated cabinets are larger than non-rated cabinets, please make sure the top of the dimension sheet refers to fire-rated cabinets and all model numbers are preceded by the prefix, "FS". The appropriate prefix for the respective Larsen's cabinet series should follow the "FS" prefix: Gemini (G), Cameo (C), Medallion (B for Brass or BZ for Bronze), Vista (V), Rota (R), Fire Hose (HC), Valve (VC), or Fire Blanket (FB). To specify aluminum trim and door, use the prefix, "AL" immediately before the model number. To specify stainless steel trim and door, use the prefix, "SS" immediately before the model number.

NOTE: For steps 2-5, please refer to attached Submittal & Detail Sheet for one of the following respective cabinet series: Architectural Series, Gemini Series, Cameo Series, Medallion Series, Vista Series, Rota Series, Fire Hose Cabinet, or Valve Cabinet.
STEP 2: Select Door Style and Door Glazing (if applicable) STEP 4: Indicate Trim Projection
STEP 3: Indicate Trim and Door Material STEP 5: Select Optional Die Cut Lettering
OPTIONAL "FIRE" HANDLE
optional fire handle
Standard Red Black White
OPTIONAL RECESSED HANDLE
optional recessed cup handle Optional recessed cup handle is available at additional cost with Solid, H-Duo or V-Duo Doors. The recessed handle must be specified with 4" projecting trims in order for the cabinet to comply with ADA projection guidelines.

FIRE-RATED CABINET DIMENSIONS
ARCHITECTURAL, GEMINI, AND MEDALLION SERIES
  Model
Number
Trim Style
and
Projection
Inside Box
Dimensions
H x W x D
Outside Trim
Dimensions
H x W**
Rough
Opening
H x W x D
Recommended
Extinguisher
Capacity
FS 2409-R1 Rec. 5/16 24 x 9½ x 5* 27½ x 13 261/8 x 115/8 x 61/8 MP2½,MP5,
MP5-A,DC2½,
DC5, HT2½", HT5
FS 2409-5R Semi-Rec. 1½ 24 x 9½ x 5* 27½ x 13 261/8 x 115/8 x 47/8
FS 2409-R3 Semi-Rec. 2½ 24 x 9½ x 5* 27½ x 13 261/8 x 115/8 x 3¾
FS 2409-R2 Rec. 5/16 24 x 9½ x 6 27½ x 13 261/8 x 115/8 x 71/8 MP2½,MP5,
MP5-A,DC2½,
DC5,MP6,MP10,
DC6,DC10,CD5
HT2½", HT5
FS 2409-6R Semi-Rec. 2½ 24 x 9½ x 6 27½ x 13 261/8 x 115/8 x 47/8
FS 2409-RM Semi-Rec. 4½ 24 x 9½ x 6 27½ x 13 261/8 x 115/8 x 27/8
FS 2409-R4 Semi-Rec. 3½ 24 x 9½ x 6 27½ x 13 261/8 x 115/8 x 4
FS 2409-RA Semi-Rec. 4 24 x 9½ x 6 27½ x 13 261/8 x 115/8 x 33/8
FS 2409-R7 Semi-Rec. 1½ 24 x 9½ x 6 27½ x 13 261/8 x 115/8 x 57/8
*Depth of these cabinets is 4¾" when supplied with aluminum door and frame. The AL 2409-5R has a 1¼" square trim.
FS 2712-R Rec. 5/16 27 x 12 x 8 30½ x 15½ 291/8 x 141/8 x 91/8 MP2½,MP5,
MP5-A,DC2½,
DC5,MP6,MP10,
DC6,DC10,CD5
PW2½,MP20,
DC20,CD10
WC-6L
HT11, HT15½
WM2½, WC2½
FS 2712-RK Semi-Rec. 1¼ 27 x 12 x 8 30½ x 15½ 291/8 x 141/8 x 81/8
FS 2712-RL Semi-Rec. 2½ 27 x 12 x 8 30½ x 15½ 291/8 x 141/8 x 7
FS 2712-RM Semi-Rec. 4½ 27 x 12 x 8 30½ x 15½ 291/8 x 141/8 x 47/8
FS 2712-RA Semi-Rec. 4 27 x 12 x 8 30½ x 15½ 291/8 x 141/8 x 53/8
FS 2720-R Rec. 5/16 27 x 20 x 8 30½ x 23½ 291/8 x 221/8 x 91/8 Two Each of the
Listed: PW2½,
MP10, DC10,
MP20, DC20, CD5,
CD10
WC-6L
HT11, HT15½
WM2½, WC2½
FS 2720-RK Semi-Rec. 1¼ 27 x 20 x 8 30½ x 23½ 291/8 x 221/8 x 81/8
FS 2720-RL Semi-Rec. 2½ 27 x 20 x 8 30½ x 23½ 291/8 x 221/8 x 7
FS 2720-RM Semi-Rec. 4½ 27 x 20 x 8 30½ x 23½ 291/8 x 221/8 x 47/8
FS 2720-RA Semi-Rec. 4 27 x 20 x 8 30½ x 23½ 291/8 x 221/8 x 53/8
FS 3012-R Rec. 5/16 30 x 12 x 8 33½ x 15½ 321/8 x 141/8 x 91/8 Same as
2712
FS 3012-RK Semi-Rec. 1¼ 30 x 12 x 8 33½ x 15½ 321/8 x 141/8 x 81/8
FS 3012-RL Semi-Rec. 2½ 30 x 12 x 8 33½ x 15½ 321/8 x 141/8 x 7
FS 3012-RM Semi-Rec. 4½ 30 x 12 x 8 33½ x 15½ 321/8 x 141/8 x 47/8
FS 3012-RA Semi-Rec. 4 30 x 12 x 8 33½ x 15½ 321/8 x 141/8 x 53/8
FS 3612-R Rec. 5/16 36 x 12 x 8 39½ x 15½ 381/8 x 141/8 x 91/8 Same as
2712
FB 3612 OPTION:
w/Shelf &
Fire Blanket
FS 3612-RK Semi-Rec. 1¼ 36 x 12 x 8 39½ x 15½ 381/8 x 141/8 x 81/8
FS 3612-RL Semi-Rec. 2½ 36 x 12 x 8 39½ x 15½ 381/8 x 141/8 x 7
FS 3612-RM Semi-Rec. 4½ 36 x 12 x 8 39½ x 15½ 381/8 x 141/8 x 47/8
FS 3612-RA Semi-Rec. 4 36 x 12 x 8 39½ x 15½ 381/8 x 141/8 x 53/8
FS 3216-R Rec. 5/16 32 x 16 x 8 35½ x 19½ 341/8 x 181/8 x 91/8 PW2½, MP20,
DC20, CD10,
CD15, WM2½, WC2½
FS 3216-RK Semi-Rec. 1¼ 32 x 16 x 8 35½ x 19½ 341/8 x 181/8 x 81/8
FS 3216-RL Semi-Rec. 2½ 32 x 16 x 8 35½ x 19½ 341/8 x 181/8 x 7
FS 3216-RM Semi-Rec. 4½ 32 x 16 x 8 35½ x 19½ 341/8 x 181/8 x 47/8
FS 3216-RA Semi-Rec. 4 32 x 16 x 8 35½ x 19½ 341/8 x 181/8 x 53/8

FIRE-RATED CABINET DIMENSIONS
VISTA,ROTA SERIES, AND FIRE HOSE & VALVE CABINETS**
MODEL NUMBER TRIM STYLE & PROJECTION INSIDE BOX DIMENSION HxWxD OUTSIDE TRIM DIMENSION - HxW ROUGH OPENING HxWxD*
FS        
FS        
FS        
FS        
FS        
*NOTE: These are rough openings for Fire-Rated cabinets. Rough openings for non-rated cabinets are smaller - please refer to the appropriate non-rated Submittal and Detail Sheet. Rough openings must be cut to the exact specifications or the fire rating will be void.

** No knock-outs are provided with fire-rated hose and valve cabinets. Pipe holes must be drilled by the installer and complete instructions are supplied with each fire-rated hose & valve cabinet.

LARSEN'S MANUFACTURING COMPANY - www.larsensmfg.com
7421 Commerce Lane N.E., Minneapolis, MN 55432 Phone: (763) 571-1181 FAX: (763) 571-6900 FLORIDA DIVISION: 3130 N.W. 17th Street, Ft. Lauderdale, FL 33311 Phone: (954) 486-3325 FAX: (954) 486-3352
©2011 Larsen's Mfg. Co.