FIRE EXTINGUISHERS
 MP, HT and DC SERIES |
MP SERIES Multi-Purpose Dry Chemical
These units contain specially fluidized and siliconized mono ammonium phosphate powder which smothers and
breaks the chain reaction on Class B fires,
fuses and insulates Class A fires, and as a non-conductor of electricity, is effective on Class C fires
involving live electrical equipment.
DC SERIES Regular Dry Chemical
These units contain specially siliconized sodium bicarbonate powder with free flowing and non-caking additives,
suitable for fire in flammable liquids, and energized electrical equipment.
NOTE: Since as of July 1, 1998, all new extinguishers installed in restaurant kitchens must be K class
rated, the DC Series no longer is recommended for use in kitchen areas.
All multi-purpose, regular or dry chemical units feature: Heavy Duty DOT Steel Cylinders,
Rugged Metal Valves and Siphon Tubes, Replaceable Molded Valve Stem Seals,
Corrosion and Impact Resistant Polyester/Epoxy Paint Finish, Pull Pin-Upright Squeeze Grip Operation,
Approved to -65ºF, Non-Toxic and Pressure Gauges. |
 WC 2½ and WC 6L SERIES |
WC SERIES Wet Chemical
Wet Chemical units are designed specifically for kitchen grease fire hazards and meet the new
K class listing now required for all extinguishers installed in restaurant kitchens. They contain a
special potassium acetate based, low PH agent, which leaves no chemical residue to clean up.
The spray applicator wand keeps the operator at a safe distance from the fire (shipped charged).
|
 PW 2½ and WM 2½ SERIES |
PW SERIES Pressurized Water
This unit is ideally suited for all industrial and commercial applications, where easy to use, positive on-off operation is important.
Water is used as the extinguishing agent, making it highly effective on deep seated Class A fires (shipped empty).
WM SERIES Water Mist
This unit is designed for use wherever there is a Class A hazard near electrical equipment and
the environment is of paramount concern. The extinguishing agent is de-ionized water, and the
wand provides greatest operator safety. There is no risk of electrical conductivity or thermal or
static shock. Ideal for use in health care, data processing, telecommunication, MRI and clean room
facilities. (shipped empty)
|
 CD SERIES |
CD SERIES Carbon Dioxide
These units contain liquid carbon dioxide under pressure.
It is discharged as a white cloud of "snow", which effectively smothers a fire.
Carbon dioxide is a clean, non-conductor of electricity for Class B and C fires.
Absolutely Rust-Free Aluminum Cylinders.
HT SERIES Halotron I
Halotron I is an EPA approved clean agent which discharges as a rapidly evaporating liquid,
leaving no residue. It effectively extinguishes Class A, B and C fires and is intended for use in
areas formerly protected by Halon 1211.
|
Standard Brackets

Optional Brackets
|
*NOTE: Standard brackets are included with all extinguishers at no additional cost.
It specified, optional brackets are only available at additional cost. All the
standard and optional brackets are designed to accommodate Larsen's extinguishers.
While most comparably sized extinguishers usually will function with the brackets above,
Larsen's cannot assume responsibility for variations in cylinder dimensions among various
extinguisher suppliers.
|
Model Number |
Nominal Capacity |
Shipping Weight |
Cylinder Diameter |
Overall Height |
Overall Width |
UL Rating |
Standard Bracket* |
Optional Bracket* |
MP2½ MP5 MP5-A MP6 MP10 MP20 |
2½ lbs. 5 lbs. 5 lbs. 6 lbs. 10 lbs. 20 lbs. |
5½ lbs. 9¼ lbs. 9¼ lbs. 12¾ lbs. 18 lbs. 38 lbs. |
3 in. 4¼ in. 4¼ in. 5 in. 5 in. 7 in. |
15½ in. 15¼ in. 15¼ in. 16 in. 20 in. 23¼ in.
|
5¾ in. 7¼ in. 7¼ in. 7¾ in. 7¾ in. 10¼ in. |
1A-10B:C 2A-10B:C 3A-40B:C 3A-40B:C 4A-80B:C 20A-120B:C |
817 1521 1521 5525 546 577 |
860 B-2, 818, 821, 860 821, 860, 818 808, 862 B-2, 846, 862 864 |
DC5 DC6 DC10 DC20 |
5½ lbs. 6 lbs. 10 lbs. 20 lbs. |
9½ lbs. 13 lbs. 18 lbs. 38 lbs. |
4¼ in. 5 in. 5 in. 7 in. |
15¼ in. 16¼ in. 20 in. 23¼ in. |
7¼ in. 8½ in. 7¾ in. 10¼ in. |
40B:C 40B:C 60B:C 120B:C |
1521 546 546 577
|
B2, 818, 821, 860 808, 862 B-2, 846, 862 864 |
WC-6L WC2½ |
6 liters 2½ gal. |
23 lbs. 34 lbs. |
7 in. 7 in. |
25 in. 24½ in. |
9 in. 9 in. |
2A:K 2A:K |
1007 1007 |
B1 864 |
| PW2½ |
2½ gal. |
7½ lbs. |
7 in. |
24½ in. |
9 in. |
2A |
1007 |
B1, 864 |
| WM2½ |
2½ gal. |
9 lbs. |
7 in. |
26 in. |
11 in. |
2A:C |
1007 |
864 |
CD5 CD1O CD15 CD20 |
5 lbs. 10 lbs. 15 lbs. 20 lbs. |
14 lbs. 28¼ lbs. 37¾ lbs. 50¾ lbs. |
5¼ in. 7 in. 7 in. 8 in.
|
17¾ in. 24 in. 30 in. 30 in. |
8¼ in. 12 in. 12 in. 13 in. |
5-B:C 10-B:C 10-B:C 10-B:C |
546 575 575 577 |
862 864 864 864 |
HT2½ HT5 HT11 HT15½ |
2½ lbs. 5 lbs. 11 lbs. 15½ lbs. |
5¼ lbs. 9½ lbs. 22½ lbs. 27½ lbs. |
3 in. 4¼ in. 6 in. 6 in.
|
15½ in. 15¼ in. 21 in. 21 in. |
5½ in. 5¾ in. 9¼ in. 9¼ in. |
2B:C 5B:C 1A:10B:C 2A:10B:C |
817 818 883 883 |
860 860 862 862 |
Paper, wood, cloth, etc. Where quenching by water or insulating by general purpose dry chemical is effective.
|
Burning liquids (Gasoline, oils, cooking fats, etc.) Where smothering action is required.
|
Fire in live electrical equipment (Motors, switches, appliances, etc.) Where a non-conductive extinguishing agent is required.
|
Cooking Media.
|
|