Larsen's Mfg.

Call us Today!    1-800-527-7367


www.larsensmfg.com
Larsen's Manufacturing

FIRE EXTINGUISHERS

MP, HT and DC SERIES
MP, HT and DC SERIES

MP SERIES Multi-Purpose Dry Chemical

These units contain specially fluidized and siliconized mono ammonium phosphate powder which smothers and breaks the chain reaction on Class B fires, fuses and insulates Class A fires, and as a non-conductor of electricity, is effective on Class C fires involving live electrical equipment.

DC SERIES Regular Dry Chemical

These units contain specially siliconized sodium bicarbonate powder with free flowing and non-caking additives, suitable for fire in flammable liquids, and energized electrical equipment. NOTE: Since as of July 1, 1998, all new extinguishers installed in restaurant kitchens must be K class rated, the DC Series no longer is recommended for use in kitchen areas.

All multi-purpose, regular or dry chemical units feature: Heavy Duty DOT Steel Cylinders, Rugged Metal Valves and Siphon Tubes, Replaceable Molded Valve Stem Seals, Corrosion and Impact Resistant Polyester/Epoxy Paint Finish, Pull Pin-Upright Squeeze Grip Operation, Approved to -65F, Non-Toxic and Pressure Gauges.

WC 2-1/2, WC 6L SERIES
WC 2½ and WC 6L SERIES

WC SERIES Wet Chemical

Wet Chemical units are designed specifically for kitchen grease fire hazards and meet the new K class listing now required for all extinguishers installed in restaurant kitchens. They contain a special potassium acetate based, low PH agent, which leaves no chemical residue to clean up. The spray applicator wand keeps the operator at a safe distance from the fire (shipped charged).
PW 2-1/2, WM 2-1/2 SERIES
PW 2½ and WM 2½ SERIES

PW SERIES Pressurized Water

This unit is ideally suited for all industrial and commercial applications, where easy to use, positive on-off operation is important. Water is used as the extinguishing agent, making it highly effective on deep seated Class A fires (shipped empty).

WM SERIES Water Mist

This unit is designed for use wherever there is a Class A hazard near electrical equipment and the environment is of paramount concern. The extinguishing agent is de-ionized water, and the wand provides greatest operator safety. There is no risk of electrical conductivity or thermal or static shock. Ideal for use in health care, data processing, telecommunication, MRI and clean room facilities. (shipped empty)
CD SERIES
CD SERIES

CD SERIES Carbon Dioxide

These units contain liquid carbon dioxide under pressure. It is discharged as a white cloud of "snow", which effectively smothers a fire. Carbon dioxide is a clean, non-conductor of electricity for Class B and C fires. Absolutely Rust-Free Aluminum Cylinders.

HT SERIES

Halotron I Halotron I is an EPA approved clean agent which discharges as a rapidly evaporating liquid, leaving no residue. It effectively extinguishes Class A, B and C fires and is intended for use in areas formerly protected by Halon 1211.

Standard Brackets
Standard Brackets

Optional Brackets
Optional Brackets

*NOTE: Standard brackets are included with all extinguishers at no additional cost. It specified, optional brackets are only available at additional cost. All the standard and optional brackets are designed to accommodate Larsen's extinguishers. While most comparably sized extinguishers usually will function with the brackets above, Larsen's cannot assume responsibility for variations in cylinder dimensions among various extinguisher suppliers.

Model
Number
Nominal
Capacity
Shipping
Weight
Cylinder
Diameter
Overall
Height
Overall
Width
UL
Rating
Standard
Bracket*
Optional
Bracket*
MP2½
MP5
MP5-A
MP6
MP10
MP20
2½ lbs.
5 lbs.
5 lbs.
6 lbs.
10 lbs.
20 lbs.
5½ lbs.
9¼ lbs.
9¼ lbs.
12¾ lbs.
18 lbs.
38 lbs.
3 in.
4¼ in.
4¼ in.
5 in.
5 in.
7 in.
15½ in.
15¼ in.
15¼ in.
16 in.
20 in.
23¼ in.
5¾ in.
7¼ in.
7¼ in.
7¾ in.
7¾ in.
10¼ in.
1A-10B:C
2A-10B:C
3A-40B:C
3A-40B:C
4A-80B:C
20A-120B:C
817
1521
1521
5525
546
577
860
B-2, 818, 821, 860
821, 860, 818
808, 862
B-2, 846, 862
864
DC5
DC6
DC10
DC20
5½ lbs.
6 lbs.
10 lbs.
20 lbs.
9½ lbs.
13 lbs.
18 lbs.
38 lbs.
4¼ in.
5 in.
5 in.
7 in.
15¼ in.
16¼ in.
20 in.
23¼ in.
7¼ in.
8½ in.
7¾ in.
10¼ in.
40B:C
40B:C
60B:C
120B:C
1521
546
546
577
B2, 818, 821, 860
808, 862
B-2, 846, 862
864
WC-6L
WC2½
6 liters
2½ gal.
23 lbs.
34 lbs.
7 in.
7 in.
25 in.
24½ in.
9 in.
9 in.
2A:K
2A:K
1007
1007
B1
864
PW2½ 2½ gal. 7½ lbs. 7 in. 24½ in. 9 in. 2A 1007 B1, 864
WM2½ 2½ gal. 9 lbs. 7 in. 26 in. 11 in. 2A:C 1007 864
CD5
CD1O
CD15
CD20
5 lbs.
10 lbs.
15 lbs.
20 lbs.
14 lbs.
28¼ lbs.
37¾ lbs.
50¾ lbs.
5¼ in.
7 in.
7 in.
8 in.
17¾ in.
24 in.
30 in.
30 in.
8¼ in.
12 in.
12 in.
13 in.
5-B:C
10-B:C
10-B:C
10-B:C
546
575
575
577
862
864
864
864
HT2½
HT5
HT11
HT15½
2½ lbs.
5 lbs.
11 lbs.
15½ lbs.
5¼ lbs.
9½ lbs.
22½ lbs.
27½ lbs.
3 in.
4¼ in.
6 in.
6 in.
15½ in.
15¼ in.
21 in.
21 in.
5½ in.
5¾ in.
9¼ in.
9¼ in.
2B:C
5B:C
1A:10B:C
2A:10B:C
817
818
883
883
860
860
862
862

Class A Fires Paper, wood, cloth, etc. Where quenching by water or insulating by general purpose dry chemical is effective. Class B Fires Burning liquids (Gasoline, oils, cooking fats, etc.) Where smothering action is required. Class C Fires Fire in live electrical equipment (Motors, switches, appliances, etc.) Where a non-conductive extinguishing agent is required. Class K Fires Cooking Media.

Contact Larsen's Mfg. - Request More Info

If you would like us to contact you or provide more information please use the online form below. Please note we respect your privacy and will not distribute your information including email address to anyone else. Thank You!
Name: Additional comments or specific questions:
E-mail:
Phone (required):
More information about:
How did you find us?
Minneapolis Division
7421 Commerce Lane N.E., Minneapolis, MN 55432
Phone: (763) 571-1181    Toll Free: 1-800-527-7367
Fax: (763) 571-6900
Florida Division
3130 N.W. 17th St., Ft. Lauderdale, FL 33311
Phone: (954) 486-3325    Toll Free: 1-800-262-3473
Fax: (954) 486-3352

©1999-2007 Larsen's Manufacturing Company
Website Design and Hosting by www.ManagementSpecialties.com