FIRE HOSE AND VALVE CABINETS
HC3030, HC3262 and HC3234 SERIES
TO SPECIFY THE HC3030, HC3262 and HC3234 SERIES:
- Insert, after "HC" the appropriate prefix for the trim and door material.
If STEEL - Use S. If ALUMINUM - Use AL.
If STAINLESS STEEL - Use SS.
If BRASS - Use B. If BRONZE - Use BZ.
(Brass and Bronze available only in the HC3030 Series)
- Select the required model number from the table below.
- Select the door style from the illustrations.
|
DIMENSIONS
|
Model Number |
Trim Style and Projection |
Inside Box Dimensions* H x W x D |
Outside Trim Dimensions H x W*** |
Rough Opening H x W x D |
Knockout Locations** E F G |
Interior Capacity |
| |
HC3030-R |
Rec. 5/16 |
30 x 30 x 8 |
33½ x 33½ |
31 x 31 x 8¼ |
4" 4" 4" |
One hose rack unit with 100 ft. of rack hose and a fire extinguisher |
| FS |
HC3030-R |
Rec. 5/16 |
30 x 30 x 8 |
33½ x 33½ |
321/8 x 321/8 x 91/8 |
-- |
| |
HC3030-RK |
Semi-Rec. 1¼ |
30 x 30 x 8 |
33½ x 33½ |
31 x 31 x 7¼ |
4" 4" 4" |
| FS |
HC3030-RK |
Semi-Rec. 1¼ |
30 x 30 x 8 |
33½ x 33½ |
321/8 x 321/8 x 81/8 |
-- |
| |
HC3030-RL |
Semi-Rec. 2½ |
30 x 30 x 8 |
33½ x 33½ |
31 x 31 x 6 |
4" 4" 4" |
| FS |
HC3030-RL |
Semi-Rec. 2½ |
30 x 30 x 8 |
33½ x 33½ |
321/8 x 321/8 x 7 |
-- |
| |
HC3030-RT |
Trimless |
30 x 30 x 8 |
-- |
--x --x8½ |
4" 4" 4" |
| |
HC3030-SM |
Surface Mtd. |
33½ x 33½ x 8½ |
33½ x 33½ |
-- |
-- |
| |
HC3232-R |
Rec. 5/16 |
32 x 32 x 8 |
35½ x 35½ |
33 x 33 x 8¼ |
4" 4" 4" |
One hose rack unit with 100 ft. of rack hose and a fire extinguisher |
| FS |
HC3232-R |
Rec. 5/16 |
32 x 32 x 8 |
35½ x 35½ |
341/8 x 341/8 x 91/8 |
-- |
| |
HC3232-RK |
Semi-Rec. 1¼ |
32 x 32 x 8 |
35½ x 35½ |
33 x 33 x 7¼ |
4" 4" 4" |
| FS |
HC3232-RK |
Semi-Rec. 1¼ |
32 x 32 x 8 |
35½ x 35½ |
341/8 x 341/8 x 81/8 |
-- |
| |
HC3232-RL |
Semi-Rec. 2½ |
32 x 32 x 8 |
35½ x 35½ |
33 x 33 x 6 |
4" 4" 4" |
| FS |
HC3232-RL |
Semi-Rec. 2½ |
32 x 32 x 8 |
35½ x 35½ |
341/8 x 341/8 x 7 |
-- |
| |
HC3232-RT |
Trimless |
32 x 32 x 8 |
-- |
--x --x8½ |
4" 4" 4" |
| |
HC3232-SM |
Surface Mtd. |
35½ x 35½ x 8½ |
35½ x 35½ |
-- |
-- |
| |
HC3234-R |
Rec. 5/16 |
34 x 32 x 8 |
37½ x 35½ |
35 x 33 x 8¼ |
4" 4" 4" |
One hose rack unit with 100 ft. of rack hose and a fire extinguisher |
| FS |
HC3234-R |
Rec. 5/16 |
34 x 32 x 8 |
337½ x 35½ |
361/8 x 341/8 x 91/8 |
-- |
| |
HC3234-RK |
Semi-Rec. 1¼ |
34 x 32 x 8 |
37½ x 35½ |
35 x 33 x 7¼ |
4" 4" 4" |
| FS |
HC3234-RK |
Semi-Rec. 1¼ |
34 x 32 x 8 |
37½ x 35½ |
361/8 x 341/8 x 81/8 |
-- |
| |
HC3234-RL |
Semi-Rec. 2½ |
34 x 32 x 8 |
37½ x 35½ |
35 x 33 x 6 |
4" 4" 4" |
| FS |
HC3234-RL |
Semi-Rec. 2½ |
34 x 32 x 8 |
37½ x 35½ |
361/8 x 341/8 x 7 |
-- |
| |
HC3234-RT |
Trimless |
34 x 32 x 8 |
-- |
--x --x8½ |
4" 4" 4" |
| |
HC3234-SM |
Surface Mtd. |
37½ x 35½ x 8½ |
37½ x 35½ |
-- |
-- |
|
NOTE: "FS" models denote Larsen's "Flame-Shield" fire-rated cabinets.
When specifying Larsen's "Flame-Shield" fire-rated cabinet option for valve and hose cabinets,
refer to the dimension chart and select from the models with an "FS" prefix.
No knock-outs are provided with fire-rated valve and hose cabinets.
Pipe holes must be drilled by installer and complete instructions are supplied with each fire-rated valve
and hose cabinet.
For complete details of the "Flame-Shield" option.
|
HC3238 and HC3242 SERIES
TO SPECIFY THE HC3238 and HC3242 SERIES:
- Insert, after "HC," the appropriate prefix for the trim and door material.
If STEEL - Use S.
If ALUMINUM - Use AL.
If STAINLESS STEEL - Use SS.
- Select the required model number from the table below.
- Select the door style from the illustrations.
|
DIMENSIONS
|
Model Number |
Trim Style and Projection |
Inside Box Dimensions* H x W x D |
Outside Trim Dimensions H x W*** |
Rough Opening H x W x D |
Knockout Locations** E F G |
Interior Capacity |
| |
HC3238-R |
Rec. 5/16 |
38 x 32 x 8 |
41½ x 35½ |
39 x 33 x 8¼ |
4" 4" 4" |
One hose rack unit with 100 ft. of rack hose, fire ext. and a Fire Dept. valve |
| FS |
HC3238-R |
Rec. 5/16 |
38 x 32 x 8 |
41½ x 35½ |
401/8 x 341/8 x 91/8 |
-- |
| |
HC3238-RK |
Semi-Rec. 1¼ |
38 x 32 x 8 |
41½ x 35½ |
39 x 33 x 7¼ |
4" 4" 4" |
| FS |
HC3238-RK |
Semi-Rec. 1¼ |
38 x 32 x 8 |
41½ x 35½ |
401/8 x 341/8 x 81/8 |
-- |
| |
HC3238-RL |
Semi-Rec. 2½ |
38 x 32 x 8 |
41½ x 35½ |
39 x 33 x 6 |
4" 4" 4" |
| FS |
HC3238-RL |
Semi-Rec. 2½ |
38 x 32 x 8 |
41½ x 35½ |
401/8 x 341/8 x 7 |
-- |
| |
HC3238-RT |
Trimless |
38 x 32 x 8 |
-- |
--x --x8½ |
4" 4" 4" |
| |
HC3238-SM |
Surface Mtd. |
41½ x 35½ x 8½ |
41½ x 35½ |
-- |
-- |
| |
HC3242-R |
Rec. 5/16 |
42 x 32 x 8 |
45½ x 35½ |
43 x 33 x 8¼ |
4" 4" 4" |
One hose rack unit with 125 ft. of rack hose, fire ext. and a Fire Dept. valve |
| FS |
HC3242-R |
Rec. 5/16 |
42 x 32 x 8 |
45½ x 35½ |
441/8 x 341/8 x 91/8 |
-- |
| |
HC3242-RK |
Semi-Rec. 1¼ |
42 x 32 x 8 |
45½ x 35½ |
43 x 33 x 7¼ |
4" 4" 4" |
| FS |
HC3242-RK |
Semi-Rec. 1¼ |
42 x 32 x 8 |
45½ x 35½; |
441/8 x 341/8 x 81/8 |
-- |
| |
HC3242-RL |
Semi-Rec. 2½ |
42 x 32 x 8 |
45½ x 35½ |
43 x 33 x 6 |
4" 4" 4" |
| FS |
HC3242-RL |
Semi-Rec. 2½ |
42 x 32 x 8 |
45½ x 35½ |
441/8 x 341/8 x 7 |
-- |
| |
HC3242-RT |
Trimless |
42 x 32 x 8 |
-- |
--x --x8½ |
4" 4" 4" |
| |
HC3242-SM |
Surface Mtd. |
45½ x 35½ x 8½ |
45½ x 35½ |
-- |
-- |
* All Hose Cabinets are available with 6" deep box, at no charge, if specified.
** No knockouts are provided for surface-mounted cabinets unless specified.
Trimless cabinets must be installed before the drywall. Plaster stop must be
behind the drywall. Trimless are not recommended for block wall installation.
*** Deduct ¾" from HxW Dimensions for Cabinets with Aluminum Door & Trim.
This does not apply to "FS" fire-rated option.
|
|